Ulvac Home

    

Search:

 


   ULVAC Technologies, Inc.
   401 Griffin Brook Drive
   Methuen, MA 01844

   Tel: 978-686-7550
   Fax: 978-689-6300


 Oil Rotary Vacuum Pumps 

TM/TMX Series Oil Mist Traps

When oil rotary vacuum pumps are started or when working in a low vacuum, the vented gas and pump oil contains oil smoke and oil drops. The TM and TMX Series ensure clean work environments, preventing indoor equipment and atmospheres from contamination by oil drops or oil smoke.

Features

  • Removes oil smoke, oil drops
    Abrasion from scattered pump oil is extremely low, greatly reducing the oil supply required by the pump.
  • Outstanding noise cancellation effect
    Extremely effective when starting pump operation from atmospheric pressure, when working in a low vacuum, and for gas ballast operation. Particularly effective for low-frequency sounds.
  • Oil recovery method can be selected (option).
    Using pumps with trapped oil inside shortens filter life and impedes pump operation. Mechanisms for recovering trapped oil can be selected according to the pump operating conditions. Contact ULVAC for the optimum mechanism.
  • Simple connection to pump
    The connection ports of the TM and TMX Series fit three standard pump vent sizes, making attachment simple. (Except for PVD, D-240DK and VS Series oil rotary vacuum pumps.)
  • Internal filter is cartridge type, for easy replacement.
    (Adapter is required to replace old-type TM-3.4.4S filter with cartridge filter.)
*1 Always use correct oil mist trap for pump's evacuation capacity.
*2 Adapters are required to connect to PVD and VS Series oil rotary vacuum pumps.
*3 Oil recovery mechanism can't be selected for TMX-1 and 2.
*4 Filters of TMX-1 and 2 (old types) can't be replaced with cartridge-type filters.
*5 Oil mist traps other than TMX40, 60 or 80 are general-purpose types. They are not suited for evacuating corrosive gases.

Specifications

Model Attachment flange (*1) Vacuum flange used Weight (kg) Material
TMX-1 Special flange/
G1 1/2
D-330(K, DK)
D-650(K, DK)
PVD-180(B) *2
PVD-360(B)
1.1 Trap : Mild steel (SPCC)
Filter : Glass wool
TMX-2 Special flange/
G2
D-950(K, DK) 1.5
TMX-40 VF40/G1·1/2 EC403 12 Trap : Stainless steel (SUS304)
Filter : Polyethylene
TMX-60 VF40/G 1·1/2 EC603 13
TMX-80 VF40/G 1·1/2 EC803 14
TMX-201 (standard, F) (*3) VF40/G 1·1/2 VD301 (for low loads)
VD401 (for low loads)
EC403 (for low loads) (*5)
8.5(9) *4 Trap : Mild steel (SGP)
Filter : Glass wool
TMX-401
(standard, F)
VF40/G 1·1/2 VD301 (for low loads) *6
VD401 (for low loads)
EC403 (for low loads)
EC603 (for low loads)
EC803 (for low loads)
10(10.5)
TM-2
(standard, F)
VG50/G2 PKS-016 5.7(6.2) Trap : Mild steel (SPCC)
Filter : Glass wool
TM-3
(standard, F)
VG80/G3 PKS-030
VS1501
10.5(11.5)
TM-4
(standard, F)
VG100/G4 PKS-070
VS2401
23.5(25)
TM-4S VG100/G4 PKS-070 (for high loads)
VS2401 (for high loads)
59

*1 Pump attachment flange : JIS B2290 vacuum flange (except for special flanges)/vent pipe screw size
*2 Adapters are required when attaching to PVD-180(B), PVD-360(B) or D-240DK.
*3 Standard : Umbrella type; F : Flange type.
*4 Weights in parentheses ( ) are weights with flanges attached.
*5 Guideline for low loads : Continuous intake pressure of up to 10 kPa.
*6 Guideline for high loads : Continuous intake pressure of up to 100 kPa.

Click here to download the PDF file.



For more information
Please Email Us
TEL : 978-686-7550/ FAX : 978-689-6300

^top   
Copyright 2008. ULVAC Technologies, Inc. All rights reserved.| Terms for using this site .