Oil
Rotary Vacuum Pumps
TM/TMX Series Oil Mist Traps
When oil rotary vacuum pumps are
started or when working in a low vacuum, the vented gas and
pump oil contains oil smoke and oil drops. The TM and TMX
Series ensure clean work environments, preventing indoor equipment
and atmospheres from contamination by oil drops or oil smoke.
Features
- Removes oil smoke,
oil drops
Abrasion from scattered pump oil is extremely low, greatly
reducing the oil supply required by the pump.
- Outstanding noise cancellation effect
Extremely effective when starting pump operation from atmospheric
pressure, when working in a low vacuum, and for gas ballast
operation. Particularly effective for low-frequency sounds.
- Oil recovery method can be selected
(option).
Using pumps with trapped oil inside shortens filter life
and impedes pump operation. Mechanisms for recovering trapped
oil can be selected according to the pump operating conditions.
Contact ULVAC for the optimum mechanism.
- Simple connection to pump
The connection ports of the TM and TMX Series fit three
standard pump vent sizes, making attachment simple. (Except
for PVD, D-240DK and VS Series oil rotary vacuum pumps.)
- Internal filter is cartridge type,
for easy replacement.
(Adapter is required to replace old-type TM-3.4.4S filter
with cartridge filter.)
| *1 |
Always use correct oil mist trap for pump's
evacuation capacity. |
| *2 |
Adapters are required to connect to PVD and VS Series
oil rotary vacuum pumps. |
| *3 |
Oil recovery mechanism can't be selected for TMX-1
and 2. |
| *4 |
Filters of TMX-1 and 2 (old types) can't be replaced
with cartridge-type filters. |
| *5 |
Oil mist traps other than TMX40, 60 or 80 are general-purpose
types. They are not suited for evacuating corrosive
gases. |
Specifications
| Model |
Attachment flange (*1) |
Vacuum flange used |
Weight (kg) |
Material |
| TMX-1 |
Special flange/
G1 1/2 |
D-330(K, DK)
D-650(K, DK)
PVD-180(B) *2
PVD-360(B) |
1.1 |
Trap : Mild steel (SPCC)
Filter : Glass wool |
| TMX-2 |
Special flange/
G2 |
D-950(K, DK) |
1.5 |
| TMX-40 |
VF40/G1·1/2 |
EC403 |
12 |
Trap : Stainless steel (SUS304)
Filter : Polyethylene |
| TMX-60 |
VF40/G 1·1/2 |
EC603 |
13 |
| TMX-80 |
VF40/G 1·1/2 |
EC803 |
14 |
| TMX-201 (standard, F) (*3) |
VF40/G 1·1/2 |
VD301 (for low loads)
VD401 (for low loads)
EC403 (for low loads) (*5) |
8.5(9) *4 |
Trap : Mild steel (SGP)
Filter : Glass wool |
TMX-401
(standard, F) |
VF40/G 1·1/2 |
VD301 (for low loads) *6
VD401 (for low loads)
EC403 (for low loads)
EC603 (for low loads)
EC803 (for low loads) |
10(10.5) |
TM-2
(standard, F) |
VG50/G2 |
PKS-016 |
5.7(6.2) |
Trap : Mild steel (SPCC)
Filter : Glass wool |
TM-3
(standard, F) |
VG80/G3 |
PKS-030
VS1501 |
10.5(11.5) |
TM-4
(standard, F) |
VG100/G4 |
PKS-070
VS2401 |
23.5(25) |
| TM-4S |
VG100/G4 |
PKS-070 (for high loads)
VS2401 (for high loads) |
59 |
| *1 |
Pump attachment flange : JIS B2290 vacuum flange (except
for special flanges)/vent pipe screw size |
| *2 |
Adapters are required when attaching to PVD-180(B),
PVD-360(B) or D-240DK. |
| *3 |
Standard : Umbrella type; F : Flange type. |
| *4 |
Weights in parentheses ( ) are weights with flanges
attached. |
| *5 |
Guideline for low loads : Continuous intake pressure
of up to 10 kPa. |
| *6 |
Guideline for high loads : Continuous intake pressure
of up to 100 kPa.
|
Click here to
download the PDF file.
For
more information |
|
TEL
: 978-686-7550/ FAX : 978-689-6300 |
|