Standard Laser Flash Thermal Constants Analyzer
TC9000
ULVAC-RIKO systems make the difference in research and development and quality control of high-tech materials. ULVAC-RIKO's system use the widely accepted Laser Flash method to measure three thermal constants: thermal conductivity, thermal diffusivity, and specific heat. Since 1970, ULVAC-RIKO has delivered over 300 laser thermal constants measuring units around the world. Now ULVAC-RIKO presents its most advanced laser thermal constants measuring system: the TC-9000. ULVAC-RIKO's TC-9000 has the latest technology to meet the increasingly diversified needs for thermal measurement.
Specifications
Model
Item |
TC-9000L |
TC-9000H |
TC-9000UHV |
|
Measurement temperature |
-150°C ~ 200°C |
Room temperature to 1500°C |
Room temperature to 2200°C |
Sample Size |
10mm dia. X 1mm to 3mm thick |
Sample irradiating light |
Glass laser output 10 J/pulse FWHM 0.1 msec/0.3 msec or less |
Sensor |
Thermocouple |
Thermocouple, IR detector |
IR detector |
Measurement |
Thermal diffusivity, specific heat capacity, thermal conductivity |
Data analysis method |
t ½ (half time) method, logarithmic method, curve fitting method* |
Footprint |
800 mm wide X 1050mm deep |
1700 mm wide X 1500 mm deep |
Power requirements |
200 VAC single phase, 10A 100 VAC, 15 A each one |
200 VAC single phase, 30A 100 VAC, 15 A each one |
200 VAC single phase, 80A 100 VAC, 15 A each one |
Cooling water requirements |
City water 5L/min or more |
Measurement atmosphere |
Low pressure helium gas |
Vacuum or air down to 150°C |
Vacuum |
Model
Item |
TC9-Low |
TC9-STEP |
TC9-SB1 |
TC9-SB2 |
|
Measurement temperature |
-150°C ~ 200°C |
Room temperature to 1000°C |
Room temperature |
Room temperature to 200°C |
Sample Size |
Same as TC-9000 |
30mm dia X 3 to 5 mm thick |
25mm square X 1mm or less thick |
Sample irradiating light |
Same as TC-9000 |
Halogen light |
Same as TC-9000 |
Sensor |
Thermocouple |
Same as TC-9000 |
Measurement properties |
Same as TC-9000 |
Thermal diffusivity |
Data analysis method |
Same as TC-9000 |
Step method |
Same as TC-9000 |
Footprint |
- |
300 mm wide X 650 mm deep |
- |
Power requirements |
- |
100 VAC, 30 A |
- |
Cooling water requirements |
City water 5L/min or more |
- |
Measurement atmosphere |
Low pressure helium gas |
Low pressure argon gas |
Air |